+964 790 142 6499 / +964 771 458 1494
Inner Highlight

DFN-9000C

DFN-9000C

 

Product Details :

 Main unit: Portable

Dimensions:L320xW205xH410

Weight:9.8kg

Technical specifications   

DEFIBRILLATOR.

(1)       Defibrillator type                               Manual, Synchronized, Asynchronized,    

(2)       Out put waveform                            Monophasic technology                                                                            

(3)       Energy accuracy                        ∠+1%

(4)  Energy selection                               0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)

(5)       Charging time                                       Maximum 8 seconds to 360 Joules

(6)  Standard Adult/Pediatric Paddles   Reusable extermal adult paddles(pediatric paddles integrated)            

.Power requirements.

(a)       AC Power supply                             110V, 60 Hz /220V,50 Hz  

(b) Vehicle Voltage             DC 12V

Internal Battery Backup

(1)      Battery type                   Rechargeable lead-acid battery

(2)      Charging time                           Time-Minimum of 4 hours for full charging    

(3)      Battery charging      During AC Power Supply operation of the device.

(4) Charging /Low Battery Indication      Red LED                

(5) Battery Capacity        100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

Display

-LED Dimensions    7’diagonal {155mm*88mm}

-Type                          High resolution true-color graphic LED

-Resolution               480X234

ECG

ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

Respiration

Measurement method: Thoracic impedance

NIBP

Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal

Temperature

Measurement range 20~45℃

Resolution 0.1℃

 

Pulse Oximetry(spO2)

Display :spo2 value, pulse histogram, waveform, Pulse

Range: 0~99%for adult, pediatric and neonatal patients

Probe :standard adult finger clip

optional pediatric Y-type clip and neonatal wrap

 

Pulse range
Pulse range: 0-255bpm

Standard parameter & configuration

 ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR

 


Baghdad Medical Devices Office

Baghdad - Saadoun Street - Al-Naser Square

info@baghdad-medical.com

+964 790 142 6499 / +964 771 458 1494